     If the temperature of the integrated screw air compressor oil is too high for a long time, the oil quality will deteriorate, so that the integrated screw air compressor oil will not achieve the desired effect, which will increase the wear of the equipment and shorten the life of the equipment. So what is the reason for the high humidity of the integrated screw air compressor? The following is the sharing of Yingpeng editor:

 

Lack of oil and aging of oil:


    This is a common problem that affects the normal service life of the oil due to the undesirable environment during long-term operation, and it is also easy to solve. Generally, you only need to replace the new oil, but the price of integrated screw air compressor oil is expensive, and only the original one can be used. Therefore, in order to save costs, you must pay attention to the use environment of the integrated screw air compressor.


Air filter blockage:

   Because most integrated screw air compressors are used in construction companies, there is a lot of dust because the environmental protection facilities of factories and mines cannot be guaranteed. The integrated screw air compressor inhales a lot of dust when it takes in air, which clogs the air filter, affects the normal operation of the air compressor, and causes high temperature tripping. Although air filters are not expensive, frequent replacement over a long period of time will affect the life of the host.


Blockage inside the cooler:

   Since the integrated screw air compressor operates in a long-term harsh environment and at a high temperature without overload, there will be carbon deposits inside the cooler, which will block the internal oil circuit, thereby reducing the oil amount in the main engine and causing the high-temperature air compressor to trip. The solution is: disassemble the cooler and pour the carbon cleaning agent into the cooler inlet, soak it for 5 to 6 hours, then pour it out, and then blow it with water and high-pressure air pipe until the water becomes clean before use.


Function of temperature control valve:

   When the integrated screw air compressor is turned on, the oil temperature is very low, the temperature control valve is closed, and the oil cannot be cooled by the fan.Principle:“The temperature of the integrated screw air compressor cannot be below 75 degrees for a long time. If it is lower than 75 degrees, there will be a lot of condensed water. The automatic drain valve cannot drain the condensed water in time. The condensed water will mix with the oil to lubricate the bearings. Just imagine what will happen to the bearings if they are lubricated with water. I won’t tell you.” When the temperature of the integrated screw air compressor reaches above 80 degrees, the temperature control valve will automatically open and the oil will be cooled through the fan heater to lower the temperature.


   The relevant content is shared here. No matter what brand the integrated screw air compressor is, how good its quality is, or how frequently it is maintained, it should be dealt with immediately as soon as a fault is found. This is responsible for the equipment, the company property, and the personal safety of the workers. Please be sure to keep this in mind.