Industrial oil-free air compressor has the advantages of low failure rate, high quality and stable product performance. In order to ensure its working efficiency and equipment life, the following points should be noted when using it:

  1. When using  Industrial Oil-free Air Compressor, the compressor protection grounding wire must be set to ensure that all metal shells of the compressor are in good contact with the earth, and the grounding resistance should meet national standards.

  2.  Keep the workplace clean and tidy: disorder is more likely to cause accidents.

  3. Pay attention to the environment in the working environment: the oil-free air compressor must not be exposed to wind and rain. If it cannot work in humid air or dark places, do not store flammable and explosive liquid carbon dioxide gas and work in places with too much dust.

  4.  Be sure to take care of the machine: For oil-free air compressors that are not selected, the air and sewage in the gas tank should be released and stored in a relatively dry environment.

  5.  Do not force the selection of machine performance: operate according to the voltage, current, response speed or load current marked on the oil-free air compressor.

  6.  Beware of electric shock: When choosing an oil-free air compressor, please do not let your body touch grounded objects (such as conduits, heating pipes, refrigerators, etc.)

  7.  Outsiders/children should not approach: Do not let irrelevant personnel approach the oil-free air compressor to avoid injury and electric shock.

  8. The air compressor is an oil-free air compressor, and the friction parts are self-lubricating. Do not add lubricating oil.

  9. If the air compressor is found to have serious air leakage, abnormal noise, or odor, it must be stopped immediately. Find out the cause, eliminate the fault, and restore it to normal before running again.

  10.  Power supply voltage: It should be noted that the power supply voltage is consistent with the voltage and current marked on the oil-free air compressor. When the power supply voltage is higher than the applicable voltage and current of the air compressor, it is likely to cause an accident and damage the air compressor. When the power supply voltage is lower than the applicable voltage and current of the air compressor, it will cause abnormal startup. Even damage the motor.

  11.  Be able to cut off the power supply in time: Develop the habit of being able to cut off the power supply in time when you are not using it after get off work. The above content is the precautions for the use of oil-free air compressors.


    During the production process, be sure to protect it carefully. If you want more information about air compressors, please pay attention to our Yingpeng website.